The newly emerging batch column called the middle vessel column presents the problem of dual composition control similar to the continuous distillation column. The degree of interaction between the two composition control loops can be assessed using the relative gain array technique. This paper presents the RGA analysis for the middle vessel column dual composition control problem. The analysis shows that the interaction between the two loops for this new column is mostly negligible due to the large time constant of the middle vessel. Furthermore, with the middle vessel column, there is a greater likelihood of reducing the interaction between control loops by varying the parameter q‘ (the ratio of the vapor rate in the rectification section of the column to the vapor rate in the stripping section of the column).