Abstract

The objective of this research is to evaluate the impact of the orientation of a building, built in clay brick, on the temperatures of its faces, to determine the best orientation that maximizes building ventilation and minimizes overheating. We first performed a climate analysis of the site using the consultant climate software, then we have evaluate the temperatures of each face using a dynamic thermal simulation. The analysis indicates that in order to benefit from good ventilation, the building should be oriented along the Southwest face; and that an orientation along the South face would reduce the exposure of the building to sunshine. Also, numerical evaluation shows an overheating of about 4° C between the South and North faces; and about 2° C between the East and West faces. In addition, the South, North, East and West faces reach maximum temperatures of 34.75° C, 38.5° C, 40.25° C and 42° C respectively. The choice of an orientation can induce overheating from the wall, up to 7.25° C. A joint analysis of these two results leads to the conclusion that the best orientation for a building in Côte d'Ivoire is the South direction.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.