Abstract
This paper proposes a new lithography method employing focused ion beam exposure and subsequent dry development. It is shown that the O2 plasma etching or reactive ion etching rate for resists exposed to gallium ions is much lower than that for resists not exposed. A comparison is made between plasma development and reactive ion development. An improvement in the resist sensitivity and contrast value γ using a CF4+O2 mixture gas for reactive ion development is discussed. It is possible to fabricate 0.5-μm-width lines and spaces in 0.6-μm-thick PMMA film at 1×10−4-C/cm2 gallium ion exposure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.