Abstract

Purpose To explore the utility of nigrosome 1 with 3-T magnetic resonance (MR) imaging to differentiate idiopathic Parkinson disease (IPD) from drug-induced parkinsonism (DIP). Materials and Methods The institutional review board approved this study, and participants gave informed consent. This study enrolled patients with DIP (n = 20) and IPD (n = 29) who underwent N-3-fluoropropyl-2-β-carbomethoxy-3-β-(4-iodophenyl)nortropane ((18)F-FP-CIT) positron emission tomography (PET) and healthy participants (n = 20). All participants underwent 0.5 × 0.5 × 1.0 mm(3) oblique axial three-dimensional multiecho-data image combination imaging to view the nigrosome 1 with 3-T imaging. Two reviewers independently assessed the nigrosome 1 without clinical information. DIP was diagnosed when no abnormality was seen at (18)F-FP-CIT PET. Diagnostic sensitivity, specificity, and accuracy of the nigrosome 1 imaging were evaluated between the IPD and DIP patients and between the IPD patients and healthy participants. Interrater agreement was assessed with Cohen κ. Results Both reviewers agreed in 63 of 69 participants (91.3%) for the presence of any abnormality on either side of the nigrosome 1 (κ = 0.825). Findings in all 29 IPD patients (100%) and three of 20 DIP patients (15%) were rated as abnormal and in 17 of 20 DIP patients (85%) they were interpreted as normal on the basis of imaging of the nitgrosome 1 (sensitivity, 100% (29 of 29); specificity, 85.0% (17 of 20); accuracy, 93.9% (46 of 49) between IPD and DIP patients). Findings in 3 of 20 healthy participants (15.0%) were interpreted as abnormal on the basis of imaging the nigrosome 1 while in the other 17 of 20 healthy participants (85.0%) they were rated as normal (sensitivity, 100% [29 of 29]; specificity, 85.0% [17 of 20]; accuracy, 93.9% [46 of 49] between IPD patients and healthy participants [κ = 0.831]). Conclusion The imaging of nigrosome 1 with 3-T imaging can differentiate DIP from IPD with high accuracy and may help to screen patients who need dopamine transporter imaging in those suspected of having DIP. (©) RSNA, 2015 Online supplemental material is available for this article.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.