Abstract

BackgroundIn-stent restenosis is the most important limitation of modern coronary angioplasty. Drug-eluting stents solve this problem but at the cost of late stent thrombosis and longer duration of dual-antiplatelet therapy. Drug-eluting balloon (DEB) technology is now available and offers an attractive option for treatment of restenosis. MethodsA cohort of 20 patients with in-stent restenosis after stenting were treated with a drug-eluting balloon and were followed up clinically and angiographically for 6 months. Results and conclusionProcedural success was achieved in all patients. 6 month clinical follow-up was available for all and 6 month angiographic follow up for 17 patients. On 6 month follow-up, 5 of the 20 patients had recurrence of angina and 4 patients had angiographic restenosis (2 focal, 2 diffuse). The mean Canadian Cardiovascular Society angina score improved significantly from 3.1 to 1.1. DEB offers a novel method of treatment for patients with in-stent restenosis with a good safety and efficacy profile.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.