Abstract

Reversible and localized blood–brain barrier disruption (BBBD) using focused ultrasound (FUS) in combination with intravascularly administered microbubbles (MBs) has been established as a non-invasive method for drug delivery to the brain. Using two-photon fluorescence microscopy (2PFM), we imaged the cerebral vasculature during BBBD and observed the extravasation of fluorescent dye in real-time in vivo. We measured the enhanced permeability upon BBBD for both 10kDa and 70kDa dextran conjugated Texas Red (TR) at the acoustic pressure range of 0.2–0.8MPa and found that permeability constants of TR10kDa and TR70kDa vary from 0.0006 to 0.0359min−1 and from 0.0003 to 0.0231min−1, respectively. For both substances, a linear regression was applied on the permeability constant against the acoustic pressure and the slope from best-fit was found to be 0.039±0.005min−1/MPa and 0.018±0.005min−1/MPa, respectively. In addition, the pressure threshold for successfully induced BBBD was confirmed to be 0.4–0.6MPa. Finally, we identified two types of leakage kinetics (fast and slow) that exhibit distinct permeability constants and temporal disruption onsets, as well as demonstrated their correlations with the applied acoustic pressure and vessel diameter. Direct assessment of vascular permeability and insights on its dependency on acoustic pressure, vessel size and leakage kinetics are important for treatment strategies of BBBD-based drug delivery.