Abstract

High strain-rate drop impact tests were performed for land grid array (LGA) packages with (electroless nickel immersion gold) ENIG metallization and lead-free solder interconnects. Sn-4Ag-0.5Cu (in wt%, SAC405), Sn-3.5Ag (in wt%), and Sn-0.7Cu (in wt%) were used for pretinning the LGA pads. SAC 405 alloy was used for the LGA-to-board mounting. Drop test results showed two distinct trends. Samples pretinned with Sn-4Ag-0.5Cu and Sn-3.5Ag showed poor drop performance while those pretinned with Sn-0.7Cu (in wt%) or without pretinning showed excellent drop performance. The dierence in behavior is related to the initial intermetallic morphology and structure. The needle shape Ni3Sn4-based intermetallics were observed for the first two cases. This led to poor adhesion between solder and NiP metallization. The samples with Sn-0.7Cu pretinning and no pretinning showed a continuous intermetallic morphology. In this case, sucient Cu improved the solder wetting and formed a continuous intermetallic morphology, leading to better drop performance. A sucient amount of Cu makes the better wetting, forming (Cu,Ni)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.