Abstract

For the solvent extraction of reprocessing plant, mixer-settler, pulsed column are operated and centrifugal extractor is expected to be used. Mixer-settler has the defect of long contact time. It comes out to cause the solvent damage by radiation in FBR fuel reprocessing. In order to escape from the damage, pulse column and centrifugal extractor should be used for FBR spent fuel. However, the characteristics in centrifugal extractor have not yet been fully analyzed, while those of mixer-settler are advanced much. There- fore, the agitation experiment was made to find out the difference of drop formation between mixer-settler and centrifugal extractor. From the results, the average drop diameter is proportional to Weber number to the power of −0.58, when the contact time is long. However, the agitation velocity did not affect the average drop size, when the contact time is less than 11.3 s.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.