Abstract

This paper describes the drone-borne dosimetry performed in two separate case studies. Two drone measurements were performed using a reference dose-rate detector measuring the ambient dose equivalent rate. A first flight was used to obtain reference measurements using a cesium-137 point source and flying at multiple speeds and different heights. A second flight was performed above the D1 radium storage of Umicore in Olen, Belgium. The main goal of this flight was to perform a scanning pattern over the area to create a dose-rate map. After the flights, we used historic measurements and a dose-rate model verified by Monte Carlo simulations using Penelope (2018) to verify the dose-rates measurements performed by the drone. Finally, we used the findings from both flights to provide recommendations regarding drone measurements using dose-rate detectors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.