Abstract

We report the electron and hole charge transport properties of semi insulating CdTe:Cl grown by the Travelling Heater Method (THM). An alpha-particle Time of Flight (TOF) method was used to measure electron and hole drift mobility, with room temperature values of 880 cm2 /Vs for electrons and 90 cm2/Vs for holes. The variation in mobility was also investigated as a function of temperature, with electron and hole mobilities at 190 K of 1150 cm2 /Vs and 20 cm2/Vs respectively. Using a Hecht analysis the electron and hole mobility-lifetime products were also measured over the same temperature range, with values at room temperature of 8times10-4 cm2/V and 7times10-5 cm 2/V respectively. Time-resolved ion beam induced charge (IBIC) imaging was used to produce micrometer resolution maps of electron drift mobility and signal amplitude, which showed excellent spatial uniformity

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.