Abstract
Abstract Simultaneous ultra-intense pulses at petawatt laser facilities enable a broad range of experiments in nuclear photonics and strong field quantum electrodynamics. These experiments often require very precise control of the time delays between pulses. We report measurements of the time delay between the two 1 PW outputs of the Extreme Light Infrastructure - Nuclear Physics (ELI-NP) facility in Romania. The short-term standard deviation of the time delay was approximately half of the pulse duration of 23 fs, and the average delay drifted with up to 100 fs/h. The drift and sporadic delay jumps were corrected using a feedback loop, which reduced the long-term standard deviation of the delay close to its short-term value. These results imply that in ELI-NP experiments using two simultaneous pulses, a temporal overlap of better than half of the pulse duration can be achieved for more than two thirds of the shots, which would enable high data rate experiments using simultaneous petawatt pulses.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.