Abstract
Recent developments in subsurface intake systems for ocean desalination plants are considering use of angled wells (slant wells) completed in permeable materials beneath the ocean floor. Conventional drawdown equations for vertical or horizontal wells are inadequate to properly describe the drawdown distribution in the vicinity of slant wells. Using the principle of superposition combined with standard well hydraulics, universal drawdown equations (UDE) are presented which calculate the drawdown distribution in the vicinity of production wells with inclination angles ranging from 0° (horizontal wells) to 90° (vertical wells). The method is computationally simple and other than the normal assumptions for standard well equations, it only requires that the calculated drawdown represent the drawdown which would be measured in a fully penetrating observation well. Solutions using the UDE are developed for confined, unconfined and semi-confined (leaky) aquifers and compared with analytical equations for vertical and horizontal wells, and with a numerical model for slant wells. The UDE is also applied to pumping test data from the Dana Point slant well project in Southern California.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.