Abstract
In the previous work, the authors showed that the double-supply-frequency pressure pulsation comes from a disturbance of the electromagnetic force occurring near the stator ends, and hence the pressure pulsation may be reduced by some way that suppresses this disturbance, e.g. by a winding grading at the stator ends. In the present work, an experiment and a numerical analysis are carried out to verify the effect of linear winding grading. The experimental data and the numerical results show that this type of grading is an effective way to reduce the pressure pulsation. In addition, the experimental data reveals that the linear winding grading improves the pump efficiency.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.