Abstract

PurposeTo evaluate the impact of double reading automated breast ultrasound (ABUS) when added to full field digital mammography (FFDM) or digital breast tomosynthesis (DBT) for breast cancer screening. MethodsFrom April 2014 to June 2015, 124 women with dense breasts and intermediate to high breast cancer risk were recruited for screening with FFDM, DBT, and ABUS. Readers used FFDM and DBT in clinical practice and received ABUS training prior to study initiation. FFDM or DBT were first interpreted alone by two independent readers and then with ABUS. All recalled women underwent diagnostic workup with at least one year of follow-up. Recall rates were compared using the sign test; differences in outcomes were evaluated using Fisher's exact test. ResultsOf 121 women with complete follow-up, all had family (35.5%) or personal (20.7%) history of breast cancer, or both (43.8%). Twenty-four women (19.8%) were recalled by at least one modality. Recalls increased from 5.0% to 13.2% (p = 0.002) when ABUS was added to FFDM and from 3.3% to 10.7% (p = 0.004) when ABUS was added to DBT. Findings recalled by both readers were more likely to result in a recommendation for short term follow-up imaging or tissue biopsy compared to findings recalled by only one reader (100% vs. 42.1%, p = 0.041). The cancer detection rate was 8.3 per 1000 screens (1/121); mode of detection: FFDM and DBT. ConclusionsAdding ABUS significantly increased the recall rate of both FFDM and DBT screening. Double reading of ABUS during early phase adoption may reduce false positive recalls.