Abstract

BackgroundThis study was designed to evaluate the clinical benefit of double-lumen port catheters in patients receiving chemotherapy and parenteral nutrition concurrently or in those with vascular access failure. The advantages, complications, indications and duration of use of double port-a-cath were considered.MethodsThirteen Brazilian patients received a double-lumen port catheter that was implanted under ultrasonographic and fluoroscopic guidance in the radiologic interventional suite.ResultsAll double-lumen port systems were successfully implanted in all patients without immediate complications. The port-a-cath was removed in two patients due to infection of the reservoir. Three deaths occurred due to underlying disease with no correlation to the port-a-cath. No temporal interference between the administration of chemotherapy and parenteral nutrition was observed.ConclusionThe double-door approach is a safe technique with low complication rates. Indications for use of the dual port are numerous and should be encouraged because of the considerable benefits for critically ill patients.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.