Abstract
Encouraged by preliminary data using double external direct-current (DC) shocks in patients with atrial fibrillation refractory to single external DC shocks, we undertook a prospective study of all patients with atrial fibrillation of > 1-month duration using a shock sequence with (1) 1 shock of 200 J anterior-posterior, (2) 1 shock of 360 J anterior-posterior, (3) 1 shock of 360 J apex-anterior, and (4) double shocks with configurations 2 and 3 delivered almost simultaneously by 2 defibrillators. The double shocks appeared to be safe and restored sinus rhythm in approximately 2 of 3 of patients in whom DC cardioversion failed with single shocks.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.