Abstract
BackgroundConcurrent chemoradiotherapy has been standard of care for unresectable esophageal carcinoma. There were no reports on proton radiotherapy (PRT) plus carbon-ion radiotherapy (CIRT) with pencil beam scanning (PBS) for esophageal carcinoma. This study evaluated the tolerability and efficiency of proton and sequential carbon-ion boost radiotherapy for esophageal carcinoma.MethodsFrom April 2017 to July 2020, 20 patients with primary esophageal carcinoma at stages II–IV were treated with PRT plus sequential CIRT with PBS. A median relative biological effectiveness-weighted PRT dose of 50 Gy in 25 fractions, and a sequential CIRT dose of 21 Gy in 7 fractions were delivered. Respiratory motion management was used if the tumor moved > 5 mm during the breathing cycle. A dosimetric comparison of photon intensity-modulated radiotherapy (IMRT), PRT, and CIRT was performed. The median times and rates of survivals were estimated using the Kaplan–Meier method. Comparison of the dose-volume parameters of the organs at risk employed the Wilcoxon matched-pairs test.ResultsTwenty patients (15 men and 5 women, median age 70 years) were included in the analysis. With a median follow-up period of 25.0 months, the 2-year overall survival and progression-free survival rates were 69.2% and 57.4%, respectively. The patients tolerated radiotherapy and chemotherapy well. Grades 1, 2, 3, and 4 acute hematological toxicities were detected in 25%, 30%, 10%, and 30% of patients, respectively. Grades 3–5 acute non-hematological toxicities were not observed. Late toxicity events included grades 1, 2, and 3 in 50%, 20%, and 10% (pulmonary and esophageal toxicity in each) of patients. Grades 4–5 late toxicities were not noted. PRT or CIRT produced lower doses to organs at risk than did photon IMRT, especially the maximum dose delivered to the spinal cord and the mean doses delivered to the lungs and heart.ConclusionsPRT plus CIRT with PBS appears to be a safe and effective treatment for esophageal carcinoma. PRT and CIRT delivered lower doses to organs at risk than did photon IMRT. Further investigation is warranted.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.