Abstract

During helical tomotherapy, gantry angle accuracy is one of the vital geometric factors that assure accurate dose delivery to the target and organs at risk adjacent to it. The purpose of this study is to investigate the dosimetric impact of gantry angle misalignment on the target volume and critical organs during helical tomotherapy treatment. Five prostate cases were chosen to calculate the effects of gantry angle deviations on both patient-specific delivery quality assurance (DQA) and helical tomotherapy treatment plans. For DQA plans, the cheese phantom was rotated for up to +/-5 degrees from the preset position to simulate the gantry angle deviations during tomotherapy. Point doses at 5 mm below the isocenter and the dose distribution for each gantry angle were measured and reconstructed, respectively. For helical tomotherapy treatment plans, the same gantry misalignment effect was simulated by adjusting the automatic roll correction for up to +/-5 degrees using Planned Adaptive software. Variations of dose volume histograms (DVHs) and isodose lines were evaluated for both target and critical organs. There was no significant difference found, however, among the point dose measurements for gantry rotation up to +/-5 degrees in DQA plans. Shifts of isodose lines could be observed for gantry rotations larger than +/-27 degrees. Dosimetric discrepancies (less than 2%) were also found among DVHs of the PTV in the cases when gantry angle misalignment was larger than +/-2 degrees. However, for DVHs of either bladder or rectum under different gantry rotations, no significant differences were detected when gantry angle errors were up to +/-5 degrees. In summary, point dose measurements alone cannot reveal the dosimetric deviation due to gantry angle misalignment in DQA plans. For a 5 degrees gantry deviation, the dose to PTV increased by 0.5% comparing to the planned dose. The influence on organs at risk, i.e., rectum and bladder, is also negligible. Further studies are needed on the dosimetric impacts of gantry angle deviations for other treatment sites.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.