Abstract

BackgroundTo evaluate the dosimetric impact of variable bladder filling on target and organ at risk (OARs) in cervical cancer patients undergoing chemoradiation. Forty consecutive patients with cervical cancer underwent radiotherapy planning as per the departmental protocol. All patients were asked to empty their bowel and bladder before simulation and catheterization was done. Normal saline was instilled into the bladder through Foleys till the patient had a maximal urge to urinate. Pelvic cast fabrication and CT simulation was done.Then, 30%, 50%, and 100% of the instilled saline was removed and rescans taken. Planning was done on full bladder (X) and the same plan applied to the contours with bladder volumes 0.7X (PLAN70), 0.5X (PLAN50), and empty (PLAN0). A dose of 50 Gy/25# was prescribed to the PTV and plans evaluated. Intensity-modulated radiotherapy plans with full bladder were implemented for each patient. Shifts in the center of mass (COM) of the cervix/uterus with variable bladder filling identified were noted. Statistical analysis was performed using SPSS software. A p value < 0.05 was considered significant.ResultsBladder volume in 70%, 50%, and empty bladder planning was 78.34% (388.35 + 117.44 ml), 64.44% (320.60 + 106.20 ml), and 13.63% (62.60 + 23.12 ml), respectively. The mean dose received by 95% PTV was 49.76 Gy + 1.30 Gy. Though the difference in target coverage was significant between PLAN100 and other plans, the mean difference was minimal. A decrease in bladder filling resulted in an increase in OAR dose. Variation in the increase in dose to OARs was not significant if bladder filling was > 78.34% and > 64.44% of a full bladder with respect to the bowel and rectal/bladder doses, respectively. Inconsistent bladder filling led to a maximal shift in COM (uterus/cervix) in the Y- and Z-axis.ConclusionBladder filling variations have an impact on cervico-uterine motion/shape, thereby impacting the dose to the target and OARs. It is recommended to have a threshold bladder volume of at least 70–75% of optimally filled bladder during daily treatment.Trial registrationInstitutional review board (IRB) registered by Drug Controller General (India) with registration number ECR/10/Ins/DC/2013. Trial Registration number - RGCIRC/IRB/44/2016, registered and approved on the 14th of May 2016.

Highlights

  • To evaluate the dosimetric impact of variable bladder filling on target and organ at risk (OARs) in cervical cancer patients undergoing chemoradiation

  • A total of forty patients with locally advanced carcinoma cervix were enrolled in the present study conducted at a tertiary cancer center in India

  • Bladder volume at 70%, 50%, and in empty bladder radiotherapy planning was calculated taking into consideration the total amount of urine formed during the simulation and the amount of saline instilled for each radiotherapy plan

Read more

Summary

Introduction

To evaluate the dosimetric impact of variable bladder filling on target and organ at risk (OARs) in cervical cancer patients undergoing chemoradiation. Concurrent chemoradiation (CTRT) plays an important role in the definitive treatment of these patients with intensity-modulated radiotherapy (IMRT) being used to intensify the target dose, while sparing adjacent normal tissues, thereby decreasing toxicity. IMRT conforms high-dose region to the target volume (TV) and tends to have a strict CTV/PTV margin. This high conformal target does not take into account tumor regression and organ motion. These factors can lead to geographical miss and should be taken into consideration during daily treatment. Minor variation in target motion can lead to underdosing or delivery of excessive dose to organ at risk (OAR) as a result of its steep dose gradient [2]

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call