<h3>Purpose/Objective(s)</h3> Reproducible patient positioning is integral to the safe and accurate delivery of radiation therapy. Commonly, lung patients are simulated with their arms up (AU) to improve dose conformality by utilizing lateral gantry angles. However, the AU position can be uncomfortable and difficult to maintain, especially in the early stage lung SBRT patient cohort, who tend to be older and less physically fit. For these patients, the physical discomfort from the AU position can lead to decreased accuracy in patient positioning and possibly treatment delivery. We sought to evaluate any potential dosimetric differences between simulating and treating SBRT lung patients in the standard AU position versus a more comfortable arms down (AD) position. <h3>Materials/Methods</h3> A sample of 10 patients undergoing lung SBRT on a noncoplanar robotic radiosurgery platform were selected. Patients were originally simulated, planned, and treated in the AD position. For ease of comparison, all treatments were replanned to 50 Gy (10 Gy x 5 fractions) regardless of tumor location. For each patient a new plan was then generated subtracting out the arms to reproduce the commonly used AU simulation position. Dosimetric quantities such as PTV coverage, PTV conformality, and other commonly accepted normal tissue constraints were compared. <i>Paired t-tests</i> of various plan metrics were calculated with a <0.05 threshold of significance. <h3>Results</h3> All plans were able to achieve adequate target coverage without violating any standard normal tissue constraints. There was no statistically significant differences observed for plans calculated in the AD versus AU positions for PTV V50Gy, lung V20Gy, esophagus D0.03cc, chest wall V30Gy, proximal bronchus D0.03cc, and distal bronchus D0.03cc. There was a statistically significant difference observed for the cord 0.03cc and cord 0.35cc doses in favor of the AD position, though in all cases the cord constraints were met. The median cord D0.35cc was 557cGy for AU verses 216cGy for AD. The median cord D0.03cc was 606cGy for AU verses 252cGy for AD. <h3>Conclusion</h3> There is no major dosimetric difference between treatment plans generated in the AU and AD positions. The exception was cord dose metrics, which showed a favorable decrease in median D0.03cc and D0.35cc in the AD position. Given the increased ease of positioning, which we believe leads to improved reproducibility and ultimately accuracy of treatment, we believe that simulating and treating patients in the AD position can be advantageous for lung SBRT treatments.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call