Abstract

A radiation-sensitive compound 2,4-hexadiyn-1,6-bis(n-butyl urethane) (HDDBU) was synthesized, characterized by FTIR spectroscopy, and introduced into a thin polyvinyl butyral film to form a radiation dosimeter for industrial irradiation facilities. The monomer polymerizes under gamma radiation, inducing change in the film spectrum in the range of 200–400nm. According to XRD spectroscopy, the film contains monomeric HDDBU in a non-crystalline state. The dose response function, radiation sensitivity, and dependences of the response on environmental factors were studied. Uncertainty of dose measurements with the proposed dosimetry system was analyzed in detail.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.