Abstract
PurposePermanent implant prostate brachytherapy plays an important role in prostate cancer treatment, but dose evaluations typically follow the water-based TG-43 formalism, ignoring patient anatomy and interseed attenuation. The purpose of this study is to investigate advanced TG-186 model-based dose calculations via retrospective dosimetric and radiobiological analysis for a new patient cohort. Methods and MaterialsA cohort of 155 patients treated with permanent implant prostate brachytherapy from The Ottawa Hospital Cancer Centre is considered. Monte Carlo (MC) dose calculations are performed using tissue-based virtual patient models. Dose–volume histogram (DVH) metrics (target, organs at risk) are extracted from 3D dose distributions and compared with those from calculations under TG-43 assumptions (TG43). Equivalent uniform biologically effective dose and tumor control probability are calculated. ResultsFor the target, D90 (V100) is 136.7 ± 20.6 Gy (85.8% ± 7.8%) for TG43 and 132.8 ± 20.1 Gy (84.1% ± 8.2%) for MC; D90 is 3.0% ± 1.1% lower for MC than TG43. For organs at risk, MC D1cc = 104.4 ± 27.4 Gy (TG43: 106.3 ± 28.3 Gy) for rectum and 80.8 ± 29.7 Gy (TG43: 78.4 ± 28.4 Gy) for bladder; D1cc = 185.9 ± 30.2 Gy (TG43: 191.1 ± 32.0 Gy) for urethra. Equivalent uniform biologically effective dose and tumor control probability are generally lower when evaluated using MC doses. The largest dosimetric and radiobiological discrepancies between TG43 and MC are for patients with intraprostatic calcifications, for whom there are low doses (cold spots) in the vicinity of calcifications within the target, identified with MC but not TG43. ConclusionsDVH metrics and radiobiological indices evaluated with TG43 are systematically inaccurate by upward of several percent compared with MC patient-specific models. Mean cohort DVH metrics and their MC:TG43 variances are sensitive to patient cohort and clinical practice, underlining the importance of further retrospective MC studies toward widespread clinical adoption of advanced model-based dose calculations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.