Abstract
Evaluate a cone-beam computed tomography (CBCT)-based daily adaptive platform in cervical cancer for multiple endpoints: (1) physics contouring accuracy of daily CTVs, (2) CTV coverage with adapted plans and reduced PTV margins versus non-adapted plans with standard-of-care (SOC) margins, (3) dosimetric improvements to CTV and organs-at-risk (OARs), and (4) on-couch time. Using a Varian Ethos™ emulator and KV-CBCT scans, we simulated the doses 15 retrospective cervical cancer patients would have received with/without online adaptation for five fractions. We compared contours and doses from SOC plans (5-15mm CTV-to-PTV margins) to adapted plans (3mm margins). Auto-segmented CTVs and OARs were reviewed and edited by trained physicists. Physics-edited targets were evaluated by an oncologist. Time spent reviewing and editing auto-segmented structures was recorded. Metrics from the CTV (D99%), bowel (V45Gy, V40Gy), bladder (D50%), and rectum (D50%) were compared. The physician approved the physics-edited CTVs for 55/75 fractions; 16/75 required reductions, and 4/75 required CTV expansions. CTVs were encapsulated by unadapted, SOC PTVs for 56/75 (72%) fractions-representative of current clinical practice. CTVs were completely covered by adapted 3mm PTVs for 71/75 (94.6%) fractions. CTV D99% values for adapted plans were comparable to non-adapted SOC plans (average difference of -0.9%), while all OAR metrics improved with adaptation. Specifically, bowel V45Gy and V40Gy decreased on average by 87.6 and 109.4 cc, while bladder and rectum D50% decreased by 37.7% and 35.8%, respectively. The time required for contouring and calculating an adaptive plan for 65/75 fractions was less than 20 min (range: 1-29 min). Improved dose metrics with daily adaption could translate to reduced toxicity while maintaining tumor control. Training physicists to perform contouring edits could minimize the time physicians are required at adaptive sessions improving clinical efficiency. All emulated adaptive sessions were completed within 30 min however extra time will be required for patient setup, image acquisition, and treatment delivery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.