Aim/Objective: Prone positioning is often used to reduce the dose to organs at risk during adjuvant breast irradiation. High tangents are used with supine treatments in patients with the low-volume nodal disease to increase nodal coverage while minimizing toxicities. Our study aims to evaluate nodal coverage for patients treated in the prone position with high tangents.Materials and Methods: Our study analyzed the plans for 20 patients with early-stage, left-sided breast cancers treated at our institution from 2018 to 2019. All patients were treated in the prone position. Axillary nodal levels I-III were contoured, and treatment plans were generated using high tangents. The heart, bilateral lungs, and breast tissue were retrospectively contoured. All plans were evaluated to a dose of 42.4 Gy in 16 fractions.Results: Level I lymph node levels had a mean coverage of 99% of the prescription dose (range: 98-100%). Similarly, level II coverage was approximately 88% (range: 65-100%). The mean coverage for level III was approximately 25% (range: 0-52%). The mean heart dose, mean lung volume receiving ≥20 Gy (V20) for the bilateral lungs, and ipsilateral V20 were 1.69 Gy, 1.64%, and 3.56%, respectively.Conclusion:Treating patients in the prone position with high tangents provides excellent coverage of axillary levels I and II, although there is minimal coverage of axillary level III. Prospective trials are needed to evaluate the clinical outcomes when treating patients with high tangents in the prone position.