Abstract

BackgroundCardiovascular implantable electronic devices (CIEDs) with physical activity (PA) recording function can continuously and automatically collect patients’ long-term PA data. The dose-response association of implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRTD)-measured PA with cardiovascular outcomes in patients at high risk of sudden cardiac death (SCD) was investigated.MethodsIn total, 822 patients fulfilling the inclusion criteria were included and divided into three groups according to baseline PA tertiles: tertile 1 (< 8.04%, n = 274), tertile 2 (8.04–13.24%, n = 274), and tertile 3 (> 13.24%, n = 274). The primary endpoint was cardiac death, the secondary endpoint was all-cause mortality.ResultsDuring a mean follow-up of 59.7 ± 22.4 months, cardiac death (18.6% vs 8.8% vs 5.5%, tertiles 1–3, P < 0.001) and all-cause mortality (39.4% vs 20.4% vs 9.9%, tertiles 1–3, P < 0.001) events decreased according to PA tertiles. Compared with patients younger than 60 years old, older patients had a lower average PA level (9.6% vs 12.8%, P < 0.001) but higher rates of cardiac death (13.2% vs 8.1%, P = 0.024) and all-cause mortality (28.4% vs 16.7%, P < 0.001) events. Adjusted multivariate Cox regression analyses showed that a higher tertile of PA was associated with a lower risk of cardiac death (hazard ratio (HR) 0.41, 95% confidence interval (CI): 0.25–0.68, tertile 2 vs tertile 1; HR 0.28, 95% CI: 0.15–0.51, tertile 3 vs tertile 1, Ptrend < 0.001). Similar results were observed for all-cause mortality. The dose-response curve showed an inverse non-linear pattern, and a significant reduction in endpoint risk was observed at the low-moderate PA level. The HR for cardiac death was reduced by half with 12.32% PA (177 min), and the HR for all-cause mortality was reduced by half with 11.92% PA (172 min). Subgroup analysis results indicated that older adults could benefit from PA and the range for achieving optimal benefits might be lower.ConclusionsPA monitoring may aid in long-term management of patients at high risk of SCD. More PA will generate better survival benefits, but even low-moderate PA is already good especially for older adults, which is relatively easy to achieve.

Highlights

  • Sudden cardiac death (SCD) is a serious public health problem worldwide, accounting for approximately 50% of all cardiovascular deaths [1]

  • Adjusted multivariate Cox regression analyses showed that a higher tertile of physical activity (PA) was associated with a lower risk of cardiac death (hazard ratio (HR) 0.41, 95% confidence interval (CI): 0.25–0.68, tertile 2 vs tertile 1; Hazard ratio (HR) 0.28, 95% Confidence interval (CI): 0.15–0.51, tertile 3 vs tertile 1, P trend < 0.001)

  • The HR for cardiac death was reduced by half with 12.32% PA (177 min), and the HR for all-cause mortality was reduced by half with 11.92% PA (172 min)

Read more

Summary

Introduction

Sudden cardiac death (SCD) is a serious public health problem worldwide, accounting for approximately 50% of all cardiovascular deaths [1]. An implantable cardioverter defibrillator (ICD) can effectively terminate malignant tachyarrhythmia, prevent SCD and reduce all-cause mortality [2]. The number of patients with cardiovascular implantable electronic devices (CIEDs) is increasing noticeably. CIEDs with PA recording function can continuously and automatically collect patients’ longterm PA data. Studies have focused on the dose-response relationship of PA and outcomes to determine the best benefit interval. The dose-response association of implantable device measured PA with cardiovascular outcomes in patients with ICDs remains unclear. Cardiovascular implantable electronic devices (CIEDs) with physical activity (PA) recording function can continuously and automatically collect patients’ long-term PA data. The dose-response association of implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRTD)-measured PA with cardiovascular outcomes in patients at high risk of sudden cardiac death (SCD) was investigated

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.