Abstract

In this work, we report some preliminary results regarding the analysis of electron spin resonance (ESR) response of soda-lime samples used for retrospective dosimetry. Six different soda-lime glass batches were evaluated after irradiation. We compared several dose reconstruction techniques: saturation method, subtraction method and g-effective, geff, approach. The differences were observed and discussed. ESR signal responses of soda-lime glass samples to different radiation doses for the triage application were investigated. Results confirmed that geff approach has potential for the identification and dosimetry of irradiated soda-lime glass samples using either additive dose method or only calibration curve.