Abstract

DONES (DEMO-Oriented Neutron Source) is to be constructed in order to investigate materials that are intended to be used for DEMO (DEMOnstration Power Plant) since they will be irradiated with very high fluxes of neutrons. A deuteron beam will bombard a lithium target situated in the so called Test Cell (TC) shielded with concrete. Monte Carlo simulations by means of the MCNP (Monte Carlo N-Particle) code were carried out to calculate both horizontal and vertical radiation dose maps in and around of the TC facility. Three geometrical configurations of the shielding and two kinds of concrete (ordinary and magnetite ones) were examined. For each case a spatial dose distribution and an accompanying errors map were provided. Advanced techniques of variance reduction were applied to compute doses in and outside of thick concrete walls. On the grounds of the obtained results a final configuration of the shielding was selected.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call