The development of technologies for using the Novac-11 pulsed electron accelerator in radiation therapy of animals with spontaneous neoplasms requires dosimetric and radiobiological studies. The studies were performed on cultured Chinese hamster V-79 fibroblasts after irradiation with 10 MeV electrons in a dose range up to 12 Gy and 60Co γ-radiation. Chemical dosimeters FBX and Fricke were used as additional test-systems. The depth dose curves were measured and the maximum dose depth of the electron beam was determined in tissue-equivalent phantoms. Cell survival and the data of chemical dosimetric systems showed that the effects of electron irradiation did not differ from that of 60Co γ-radiation. It was concluded that the use of Novac-11 in the therapy of animals with spontaneous neoplasms is advisable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.