Abstract

PurposeThis study aimed to evaluate characteristics of dose fall-off pattern for linear accelerator based frameless stereotactic radiotherapy and radiosurgery using two different techniques, three-dimensional conformal radiotherapy and volumetric modulated arc therapy. Materials and methodsThe data from thirty patients who underwent frameless stereotactic radiotherapy/radiosurgery were considered for this analysis. These included 11 patients treated using three-dimensional conformal radiation and 19 patients treated with volumetric modulated arc therapy. Dose fall-offs in six predetermined directions from the edge of planning target volume and in direction of organs at risk were evaluated. These included determining dose fall-off (distance range) of 100%–80%, 100%–50%, 100%–20% from the treatment planning system. The first derivative (percentage of dose fall-off per millimetre) and second derivative (percentage of dose per square millimetre) of the dose fall-off was calculated. ResultsThe dose fall-off is sharpest in the organ at risk direction if the organ at risk is hugging the planning target volume. However, for organs at risk separated from the planning target volume sharpest dose fall-off could be in either planning target volume superior or inferior direction. Three-dimensional conformal radiotherapy plans had a mean±SD of 14±2 beams (range: 11–17). Volumetric modulated arc therapy planning comprised of arc angles with sum±SD of 953±172.5° (range: 610°–1170°). Mean±SD for the single sharpest dose fall-off for all patients receiving three-dimensional conformal radiotherapy was 11.3±4.7%·mm−1, 7.8±4.8%·mm−1 and 7.1±5.6%·mm−1 for 100%–80%, 100%–50% and 100%–20% fall-off ranges respectively. For volumetric modulated arc therapy, the mean±SD of the single sharpest fall-off was 10.4±4.6%·mm−1, 7.8±3.0%·mm−1 and 7.3±5.0%·mm−1 for 100%–80%, 100%–50% and 100%–20% range. All organs at risk doses received doses within limits prescribed by AAPM-TG report 21. Mean dose to monitor units (MU) modulation factor MF=total MU deliveredprescription dose in cGy for three-dimensional conformal radiotherapy and volumetric modulated arc therapy were 1.97±1.0 MU·cGy−1 and 2.5±0.75 MU·cGy−1 respectively. ConclusionOur study presents the dose fall-off patterns in context of frameless stereotactic radiation therapy. We have presented the dose fall-off data in the framework of three-dimensional conformal radiotherapy and volumetric modulated arc therapy in brain lesions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.