Abstract

Accidental exposure dose assessment by electron spin resonance (ESR) technique from the free radicals generated in a cotton handkerchief has been attempted in this investigation. The cotton handkerchief, a common material carried by individuals, was taken as the medium for free radical estimation. About 55 mg of the irradiated piece of cloth was loaded into a quartz tube and the dose dependence of the ESR signal at g=2.0026 was measured at room temperature, using a Bruker ESP-300 ESR spectrometer in X-band (9.74 GHz). The intensity of this signal was found to be proportional to the dose in the range of 1–1000 Gy. The stability of the free radicals with time of storage was followed. Dependence of dose rate as well as the presence of water on the yield of free radicals were also investigated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.