Abstract

Metal ion toxicity is not simply related to the total concentration but to the free or labile metal ion concentration. One of the techniques that can measure the free metal ion concentration is the Donnan Membrane Technique (DMT). However, this method has limitations in terms of a relatively high detection limit (in relation to typical environmental concentrations) and a long equilibration time. We have therefore developed the Flux Donnan Membrane (FDM) Technique, which is a dynamic modification of the standard DMT with improved detection limits and a more rapid response. We show that experimental calibrations of metal ion transport in the FDM can be used to measure [M]free under conditions of either solution-controlled or membrane-controlled diffusive transport. The FDM was used to measure cobalt binding isotherms by a humic substance over a large range of free Co concentrations and pH.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.