Abstract

Abstract : Results of performance testing of commercial air-purifying negative pressure respirators (NPR) are described. A series of tests were performed using human subjects to determine the corn oil protection factors of NPR systems. A series of Protection Factor (PF) tests were performed on 12 commercially available respirators. These tests determined the ability of the respirator to keep small particulates out of the respirator oro-nasal cavity and protect the user from biological warfare agents. The particulates used in the test were made up of a corn oil aerosol. Testing occurred over several weeks, and humans were used as the test subjects. Testing involved a standard series of exercises designed to represent the range of movements that stress the face seals of respirators. All the respirators provided the wearers some protection from the aerosol, and several of them provided excellent protection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.