Abstract

The laryngeal mask airway was inserted in 10 cadavers. At postmortem the chest was opened and an infusion set primed with a dilute barium solution was inserted into the oesophagus and ligated in place. A cricoid force of 43 N was then applied and the infusion set was positioned so that when the clamp was opened it generated a pressure of 7.8 kPa within the oesophagus. The cricoid pressure was able to stop the flow of fluid into the oesophagus. This demonstrates that cricoid pressure is effective in preventing reflux at intragastric pressures which are encountered clinically and the presence of the laryngeal mask airway does not compromise this.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.