Abstract

To investigate whether the insertion of a gel-based marker at the time of stereotactic breast biopsy allows subsequent preoperative localization to be performed under ultrasound guidance. One hundred consecutive women who underwent either a 10 G stereotactic vacuum-assisted breast biopsy or 14 G stereotactic core biopsy with marker placement, followed by wire localization and surgical excision were identified. All had mammographic abnormalities not initially visible with ultrasound. The method of preoperative localization was recorded and its success judged with reference to the wire position on the post-procedure films relative to the mammographic abnormality and the marker. Histopathology data were reviewed to ensure the lesion had been adequately excised. Eighty-three women (83%) had a successful ultrasound-guided wire localization. Successful ultrasound-guided localization was more likely after stereotactic vacuum biopsy (86%) compared to stereotactic core biopsy (68%), although this did not quite reach statistical significance (p=0.06). The routine placement of a gel-based marker after stereotactic breast biopsy facilitates preoperative ultrasound-guided localization.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call