Abstract

Pedicle screw loosening is a complication of spinal instrumentation in osteoporotic patients. Dual-energy x-ray absorptiometry scans are not able to detect variations in bone mineral density (BMD) within specific regions of vertebrae. The purpose of this study was to investigate whether spine T scores correlate with cortical and cancellous BMD of pedicles and other 6 anatomical regions of lumbar spine. Eleven cadaveric spines with a mean age of 73 years were digitally isolated by applying filters for cortical and cancellous bone on computed tomography images. Eleven L5 vertebrae were separated into 7 anatomical regions of interest using 3-dimensional software modeling. Hounsfield units (HU) were determined for each region and converted to cortical and cancellous BMD with calibration phantoms of known BMD. Correlations between T scores and HU values were calculated using Pearson correlation coefficient. Mean vertebral T score was 0.15. Cortical BMD of pedicles was strongly correlated with T score (R 2 = 0.74). There was moderate correlation between T score and cortical BMD of lamina, inferior articular process (IAP), superior articular process (SAP), spinous process, and vertebral body. There was weak correlation between T score and cortical BMD of transverse process (R 2 = 0.16). Cancellous BMD of vertebral body was strongly correlated with T score (R 2 = 0.82). There was moderate correlation between T score and cancellous BMD of pedicles, spinous process, and transverse process. There was weak correlation between T scores and cancellous BMD of lamina, IAP, and SAP. There is a strong correlation between T scores and cortical BMD of lumbar pedicle. There is strong correlation between T scores and cancellous BMD of vertebral body. Cortical and cancellous BMD of transverse process and lamina were weakly correlated with T score and less affected by osteoporosis. Patients with osteoporosis may especially benefit from the development of extrapedicular fusion strategies due to the relatively higher bone density of these fixation sites.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.