Abstract
Radial head alignment is the key to determine elbow reduction after treatment of subluxations or Monteggia fractures. The radiocapitellar ratio (RCR) quantifies the degree of subluxation, by evaluating radial head alignment with the capitellum of the humerus; this ratio is reproducible when measured on true lateral radiographs of nonsubluxated elbows. However, the impact of beam angulation on RCR measurement is unknown. Our hypotheses were that the RCR of the nonsubluxated elbow would remain in the normal range as the beam angle changed and that the RCR variability would increase for the subluxated elbow with small deviations in the beam angle. Radiographs were taken of six healthy cadaveric extremities using beam angles ranging from -20° to 20° along the inferosuperior axis and from -20° to 20° along the dorsoventral axis. The same views then were taken of the six arms with anterior radiocapitellum subluxation followed by posterior radiocapitellum subluxation. RCRs were measured by one observer. As a reference value, the RCR was measured in the 0° to 0° position and the difference between each RCR in a nonreference position was subtracted from each RCR reference to obtain the delta-RCR. An ANOVA was performed to assess the main and interactive effects on the RCR measured in each C-arm position compared with the RCR measured on a true lateral radiograph. The RCR remained in the normal range even as the beam angle of the C-arm varied between -20° and 20°. The position of the beam did not affect the RCR in anteriorly subluxated elbows (p = 0.777), whereas RCR variation increased especially in the presence of posterior radial head subluxation when the C-arm position was 10° or more out of plane (p = 0.006). The inferosuperior malposition of the C-arm had a greater impact on quantification of radial head alignment measurement. Despite that, the RCR measurement is reliable in reduced and subluxated elbows on lateral radiographs with a C-arm position deviation of as much as 20°. Identification of a subluxated elbow could be made on any lateral radiograph with a beam angulation deviation of as much as 20°. This suggests that the RCR is a useful diagnostic tool for clinical and research purposes, although for subluxated elbows, it is important to pay careful attention to the inferosuperior position of the C-arm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.