Abstract

BackgroundBile duct injury and conversion-to-open–surgery rates remain unacceptably high during laparoscopic and robotic cholecystectomy. In a recently published randomized clinical trial, using near-infrared fluorescent cholangiography with indocyanine green intraoperatively markedly enhanced biliary-structure visualization. Our systematic literature review compares bile duct injury and conversion-to-open–surgery rates in patients undergoing laparoscopic or robotic cholecystectomy with versus without near-infrared fluorescent cholangiography. MethodsA thorough PubMed search was conducted to identify randomized clinical trials and nonrandomized clinical trials with ≥100 patients. Because all near-infrared fluorescent cholangiography studies were published since 2013, only studies without near-infrared fluorescent cholangiography published since 2013 were included for comparison. Incidence estimates, weighted and unweighted for study size, were adjusted for acute versus chronic cholecystitis, and for robotic versus laparoscopic cholecystectomy and are reported as events/10,000 patients. All studies were assessed for bias risk and high-risk studies excluded. ResultsIn total, 4,990 abstracts were reviewed, identifying 5 near-infrared fluorescent cholangiography studies (3 laparoscopic cholecystectomy/2 robotic cholecystectomy; n = 1,603) and 11 not near-infrared fluorescent cholangiography studies (5 laparoscopic cholecystectomy/4 robotic cholecystectomy/2 both; n = 5,070) for analysis. Overall weighted rates for bile duct injury and conversion were 6 and 16/10,000 in near-infrared fluorescent cholangiography patients versus 25 and 271/10,000 in patients without near-infrared fluorescent cholangiography. Among patients undergoing laparoscopic cholecystectomy, bile duct injuries, and conversion rates among near-infrared fluorescent cholangiography versus patients without near-infrared fluorescent cholangiography were 0 and 23/10,000 versus 32 and 255/10,000, respectively. Bile duct injury rates were low with robotic cholecystectomy with and without near-infrared fluorescent cholangiography (12 and 8/10,000), but there was a marked reduction in conversions with near-infrared fluorescent cholangiography (12 vs 322/10,000). ConclusionAlthough large comparative trials remain necessary, preliminary analysis suggests that using near-infrared fluorescent cholangiography with indocyanine green intraoperatively sizably decreases bile duct injury and conversion-to-open–surgery rates relative to cholecystectomy under white light alone.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call