Abstract

During airway pressure release ventilation (APRV), tidal ventilation occurs between the increased lung volume established by the application of continuous positive airway pressure (CPAP) and the relaxation volume of the respiratory system. Concern has been expressed that release of CPAP may cause unstable alveoli to collapse and not reinflate when airway pressure is restored. To compare pulmonary mechanics and oxygenation in animals with acute lung injury during CPAP with and without APRV. Experimental, subject-controlled, randomized crossover investigation. Anesthesiology research laboratory, University of South Florida College of Medicine Health Sciences Center. Ten pigs of either sex. Acute lung injury was induced with an intravenous infusion of oleic acid (72 micrograms/kg) followed by randomly alternated 60-min trials of CPAP with and without APRV. Continuous positive airway pressure was titrated to produce an arterial oxyhemoglobin saturation of at least 95% (FIO2 = 0.21). Airway pressure release ventilation was arbitrarily cycled to atmospheric pressure 10 times per minute with a release time titrated to coincide with attainment of respiratory system relaxation volume. Cardiac output, arterial and mixed venous pH, blood gas tensions, hemoglobin concentration and oxyhemoglobin saturation, central venous pressure, pulmonary and systemic artery pressures, pulmonary artery occlusion pressure, airway gas flow, airway pressure, and pleural pressure were measured. Tidal volume (VT), dynamic lung compliance, intrapulmonary venous admixture, pulmonary vascular resistance, systemic vascular resistance, oxygen delivery, oxygen consumption, and oxygen extraction ratio were calculated. Central venous infusion of oleic acid reduced PaO2 from 94 +/- 4 mm Hg to 52 +/- 9 mm Hg (mean +/- 1 SD) (p < 0.001) and dynamic lung compliance from 40 +/- 6 mL/cm H2O to 20 +/- 6 mL/cm H2O (p = 0.002) and increased venous admixture from 13 +/- 3% to 32 +/- 7% (p < 0.001) in ten swine weighing 33.3 +/- 4.1 kg while they were spontaneously breathing room air. After induction of lung injury, the swine received CPAP (14.7 +/- 3.3 cm H2O) with or without APRV at 10 breaths per minute with a release time of 1.1 +/- 0.2 s. Although mean transpulmonary pressure was significantly greater during CPAP (11.7 +/- 3.3 cm H2O) vs APRV (9.4 +/- 3.8 cm H2O) (p < 0.001), there were no differences in hemodynamic variables. PaCO2 was decreased and pHa was increased during APRV vs CPAP (p = 0.003 and p = 0.005). PaO2 declined from 83 +/- 4 mm Hg to 79 +/- 4 mm Hg (p = 0.004) during APRV, but arterial oxyhemoglobin saturation (96.6 +/- 1.4% vs 96.9 +/- 1.3%) did not. Intrapulmonary venous admixture (9 +/- 3% vs 11 +/- 5%) and oxygen delivery (469 +/- 67 mL/min vs 479 +/- 66 mL/min) were not altered. After treatment periods and removal of CPAP for 60 min, PaO2 and intrapulmonary venous admixture returned to baseline values. Intrapulmonary venous admixture, arterial oxyhemoglobin saturation, and oxygen delivery were maintained by APRV at levels induced by CPAP despite the presence of unstable alveoli. Decrease in PaO2 was caused by increase in pHa and decrease in PaCO2, not by deterioration of pulmonary function. We conclude that periodic decrease of airway pressure created by APRV does not cause significant deterioration in oxygenation or lung mechanics.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.