Abstract

The purposes of this study were to analyze and compare the functional outcomes and radiological changes around the press-fit humeral components in two contemporary medialized reverse total shoulder arthroplasty (RTSA) systems at a minimum of 5-year follow-up. Between December 2003 and December 2015, 249 consecutive RTSAs were performed at our hospital. Of these, 68 primary uncemented RTSA met our inclusion criteria. The Constant-Murley score (CMS), the modified Constant score, a visual analog scale (VAS) and active shoulder range of motion (ROM) were measured pre- and postoperatively. Radiological assessment was performed by plain radiographs at a minimum of 5years postoperatively. At a mean follow-up of 80.2months, there was no significant difference (p = .59) between the postoperative functional scores and range of motion of the two groups (Delta Xtend and Lima SMR). Radiological data of stress-shielding were observed in 38 patients (55.9%) being slightly more frequent in the Lima SMR group (21 patients) than in the Delta Xtend group (17 patients) (p = .62). Our study shows that the good functional results are similar between the two uncemented RTSA systems used and that they do not depend on the presence of radiological changes (stress-shielding) in the humeral stem at a minimum 5-year follow-up.