Abstract

This paper reports on space charge measurements on /spl sim/1.5 mm thick XLPE and polyolefinic plaques with two different treatments and semicon electrodes, namely, the same XLPE and polyolefin loaded with carbon. Samples were subjected to both DC and 50 Hz AC electric stresses in the region of 25 kV/mm (at room temperature). Measurements of charge profiles and stress distributions were made using the modified laser induced pressure propagation system. Emphasis has been placed on comparing the space charge characteristics of the two insulation systems with the different sernicon electrodes. The effects of sample treatment (i.e. degassing) on the space charge dynamics are also presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.