Abstract

To comparatively evaluate the elution of residual monomers (bis-GMA, bis-EMA, TEG-DMA, and HEMA) from two self-adhesive flowable resin composites, a giomer, and a nano-flowable resin composite over five different time intervals, using high-performance liquid chromatography (HPLC). Four flowable resin composites were investigated (Vertise Flow, Constic, Beautifil Flow Plus F03, and Filtek Z350 XT). Immediately after polymerization, each sample was immersed in 75% ethanol/water solution and stored in amber-colored bottles at room temperature. HPLC analysis was performed at predefined time intervals: 1 h, 24 h, 4 days, 8 days and 16 days. The extraction solution was changed after each analysis. Data were analyzed with repeated-measures ANOVA and one-way ANOVA with Tukey's post-hoc test at p < 0.05. The highest mean concentration of residual monomers was eluted from Beautifil, followed by Filtek, and both were significantly higher (p < 0.05) than the mean concentration of eluates from self-adhesive resin composites (Vertise Flow and Constic). Vertise Flow released significantly higher concentrations of HEMA than all the other tested materials. At 1 h post-immersion, 52.2% of monomers were eluted, and continued to elute at a reduced rate throughout the study duration. TEG-DMA was the fastest monomer to leach out, while bis-GMA exhibited significantly higher total mean concentration. The elution rate was significantly dependent on the molecular weight of the eluted monomers. No specific elution behavior can be attributed to self-adhesive RBCs. Elution of residual monomers is dependent on each material's composition, resin matrix characteristics, and the monomer's molecular weight.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call