Abstract

ObjectiveTo investigate whether the radiographic results are affected by cage position in single‐level transforaminal lumbar interbody fusion (TLIF).MethodBetween January 2016 and June 2018, 130 patients (62 males and 68 females, average age: 55.28 ± 10.11 years) who underwent single‐level TLIF were analyzed retrospectively. Standing lateral radiographs of the lumbar spine were collected and evaluated preoperatively, postoperatively, and at the time of last follow‐up. Cage position in the fused segment was recorded using a central point ratio (CPR), which indicated the cage position. CPR is calculated by dividing the distance between the cage center point and the posterior extent of the superior endplate of the inferior vertebra by the length of the superior endplate of the inferior vertebra. Based on cage positions, the patients were divided into three groups: Anterior Group (n = 38); Middle Group (n = 68); and Posterior Group (n = 24). Segmental lumbar lordosis (SLL), foraminal height (FH), posterior disc height (PDH), and anterior disc height (ADH) were evaluated. A subanalysis was also performed on cage height within each group.ResultsThe average follow‐up time of the patients was 35.20 ± 4.43 months. The mean values of CPR in Anterior Group, Middle Group, and Posterior Group were 0.64, 0.51, and 0.37, respectively. The FH, PDH, and ADH were significantly increased after TLIF in all groups (P < 0.05). There were significant differences in increase of SLL in Anterior Group (4.4°) and Middle Group (3.0°), but not in Posterior Group (0.3°). Furthermore, in the comparison of the three groups, the increase of SLL, FH, and PDH was statistically different (P < 0.05), while not for ADH (P > 0.05). The significant correlations in surgery were: CPR and ΔSLL (r = 0.584, P < 0.001), CPR and ΔFH (r = −0.411, P < 0.001), and CPR and ΔPDH (r = −0.457, P < 0.001). However, ADH had a positive correlation with cage height when the cage was located in anterior and middle of the endplate. Moreover, cage height had a positive correlation with SLL when the cage was located anteriorly and had a negative correlation with SLL when the cage was located posteriorly. FH and PDH both had a positive correlation with cage height in any cage position.ConclusionThe cage located in different positions has different effects on radiographic results in single‐level TLIF. A thicker cage located anteriorly will gain maximum SLL and avoid the reduction of FH and PDH.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.