Abstract

BACKGROUND: The NOGA (Biosense Webster, Markham, ON, Canada) injection catheter is an innovative navigational device that provides an ideal platform for intra-myocardial injection material. However, injection through a long (1.91 m), narrow (27G) nitinol needle could result in deterioration in the integrity and functionality of DNA. METHODS: To test this possibility, DNA in plasmid form (pcDNA3.1) containing the Lac Z transgene (250 micro l) was passed through the NOGA needle using a hand-held 1 cc syringe at a gentle hand injection pressure (43 +/- 3 PSI, 3.0 +/- 0.2 kg/cm(2)) or at maximal manual pressure (90 +/- 6 PSI, 6.3 +/- 0.4 kg/cm(2)), either once or 20 times. This DNA, compared to DNA not passed through the NOGA needle (control), was then used to transfect primary cultures of rat skin fibroblasts (FB) from Fisher 344 rats and the cells were subsequently stained for beta galactosidase (betagal). RESULTS: Transfection efficiency was significantly reduced by passing the DNA through the needle at both 43 +/- 3 PSI (78 +/- 4% of control, n = 10, P < 0.05 versus control) and 90 +/- 6 PSI (66 +/- 4 % of control, n = 10, P < 0.01 versus control, P < 0.02 versus 43 +/- 3 PSI). Passage of the DNA through the NOGA needle 20 times resulted in a transfection efficiency of only 5 +/- 1% of control (n = 20, P < 0.1 x 10(-11) versus control). Capillary Electrophoresis revealed that the reduction in transfection efficiency was due to a conformational change in the DNA from predominantly supercoiled to nicked and linearized DNA. Transfection efficiency as compared with control decreased as the concentration of the DNA solution which was passed through the needle was increased from 0.3 micro g/ micro l to 2.4 micro g/ micro l. Recovery experiments confirmed that the reduction in transfection efficiency was not due to loss of DNA by binding to the NOGA needle. CONCLUSION: These results suggest that DNA is susceptible to shear forces when injected through the NOGA needle even at nominal clinical injection pressures, suggesting that careful and controlled injections will be required to achieve optimal gene integrity and expression.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.