Neutron capture therapy (NCT) by 10B and 157Gd agents is a unique irradiation-based method which can be used to treat brain tumors. Current study aims to quantitatively evaluate the relative biological effectiveness (RBE) and dose distributions during the combined BNCT and GdNCT modalities through a hybrid Monte Carlo (MC) simulation approach. Snyder head phantom as well as a cubic hypothetical tumor was at first modeled by Geant4 MC Code. Then, the energy spectra and dose distribution relevant to the released secondary particles during the combined Gd/BNCT were scored for different concentrations of 157Gd and 10B inside tumor volume. Finally, the scored energy spectra were imported to the MCDS code to estimate both RBESSB and RBEDSB values for different 157Gd concentrations. The results showed that combined Gd/BNCT increases the fluence-averaged RBESSB values by about 1.7 times when 157Gd concentration increments from 0 to 2000µg/g for both considered cell oxygen levels (pO2=10% and 100%). Besides, a reduction of about 26% was found for fluence-averaged RBEDSB values with an increment of 157Gd concentration in tumor volume. From the results, it can be concluded that combined Gd/BNCT technique can improve tumor coverage with higher dose levels but in the expense of RBEDSB reduction which can affect the clinical efficacy of the NCT technique.