Abstract
Preservation of intracochlear structures and residual hearing has become a major concern in modern cochlear implant. Consequently, many efforts have been made to minimize intraoperative trauma, especially while cochlear fenestration and electrode insertion. Building on the core concept of "soft surgery", a modified approach, described as diving technique for cochlear implant electrode array insertion is proposed. Steps and technical points are presented with figures, video and review of relevant anatomy. This novel diving technique is operationally feasible and safe, promising to minimize intraoperative invasion and thus preserve residual hearing in cochlear implant.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.