Abstract

Diurnal variation in plasma concentrations of nelfinavir and ritonavir has previously been described. Plasma concentrations of 29 pharmaco-kinetic profiles with indinavir, amprenavir and saquinavir were evaluated, and a statistically significant median difference of 57.6% was found between morning and evening, with the morning C through being higher than the evening C through . Consequently, a change in dosing intervals might result in more balanced plasma protease inhibitor concentrations, thereby decreasing toxicity and the risk of virological failure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.