Abstract

In an investigation of the flow characteristics of a recharge pit used for artificial ground-water recharge purposes, diurnal variations of a cyclic nature were detected in the intake rate. The output from soil water pressure sensors installed between the base of the pit and the water table indicated similar cyclic variations. The maximum intake rate occurred regularly each day at approximately 2 a.m. - 3 a.m. and the minimum approximately 12 hr later. It is concluded that these variations are due to the activity of algae on the base of the pit and in the top layer of sand. Diurnal peaks and troughs of the algae oxygen production result in changes in the hydraulic conductivity of the profile. This would appear to be related to changes in the volume of the occluded oxygen which exists as bubbles in the soil pores. These reduce the flow area available for recharge and thus cause a reduction in the intake rate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.