Abstract

To the authors' knowledge, there has not been an ultrasound study of the vulnerable vessels in a C3-7 cervical nerve root block (CNRB). To evaluate the prevalence of vulnerable vessels around the target of a CNRB at the cervical nerve root of C3-7 levels in a clinical setting. Retrospective, cross-sectional study. General teaching hospital, rehabilitation unit. A total of 104 patients complaining of neck or arm pain with no prior surgical history and who had undergone a CNRB at an outpatient clinic from May 2015 to December 2017 were included. The prevalence of vulnerable vessels as seen on a preprocedure ultrasound scan around the target of a CNRB at the cervical nerve root of C3-7 levels. Out of 104 cases, the C3 level had 7 blood vessels (8.33%), the C4 level had 14 blood vessels (13.86%), the C5 level had 17 blood vessels (16.35%), the C6 level had 27 blood vessels (25.96%), and the C7 level had 31 blood vessels (29.81%) either at the targeted cervical nerve root or at the site of the imaginary needle's projected pathway to the targeted cervical nerve root. There was a substantial prevalence of vulnerable vessels either at the targeted nerve root or at the site of the needle's projected pathway to the nerve root.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call