Abstract

This paper deals with the prediction of shaft resistance of single driven pile based on Meyerhoff formulation and empirical method based on SPT test. The accuracy of these predictions was evaluated by comparing the results with static load test (SLT) and dynamic loading test analyzed by Pile Driving Analyzer (PDA) and Case Pile Wave Analysis Program (CAPWAP) programs. The data for this study was collected from University Riau Hospital Project in Pekanbaru. The result of static and dynamic pile load test shows that only a small capacity of end resistance was mobilized due to insufficient pile deformation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.