Abstract

ABSTRACTConcentration levels of 12 PCB congeners (PCB-18, 28, 31, 44, 52, 101, 153, 118, 138, 149, 180 and 194) were determined in soil, dust, sediment and water samples collected at Ijora Olopa Power Station, Lagos, Nigeria. The calibration factors of target PCBs were estimated to test the linearity of the GC-ECD within a concentration of 0.025 ng/µL to 0.400 ng/µL. RSD of the calibration factors ranged from 4.6% to 12.3%, indicating a good response. Mean total PCBs in samples increased in the order water < soil < dust < sediment, with average values of 23.0 ng/mL, 27.3 ng/g, 272.6 ng/g, and 510.6 ng/g respectively. One way ANOVA revealed the mean concentrations of PCBs in the four sample types to be statistically different. The study provides a baseline report on the presence of PCBs in environmental samples from an electrical power facility in Lagos, Nigeria.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.